• Thu, November 13, 2025
Facebook X-twitter Instagram Youtube LinkedIn Spotify
  • GC Solar: 17,95 GW
  • GD Solar: 41,3 GW
  • TOPCon Modules: $0,088/W
  • P-Type Cells: $0,034/W
  • N-Type Cells: $0,032/W
  • HJT Modules: $0,10/W
  • N-Type Wafer: US$0,128/pc
  • Polysilicon: US$ 19,00/kg
  • GC Solar: 17,95 GW
  • GD Solar: 41,3 GW
  • TOPCon Modules: $0,088/W
  • P-Type Cells: $0,034/W
  • N-Type Cells: $0,032/W
  • HJT Modules: $0,10/W
  • N-Type Wafer: US$0,128/pc
  • Polysilicon: US$ 19,00/kg
  • advertise here
  • About us
  • Expedient
logo site solar channel
  • News
    • energy storage
    • Market and Prices
    • Investments & Business
    • Policy and Regulation
  • Articles
    • Batteries
    • Photovoltaic structures
    • Photovoltaic inverters
    • Opinion
  • Renewable
  • Latam
  • Blog
  • Solar Energy Companies
  • Integrators
  • Magazine
    • Magazine Canal Solar
    • Conecta Magazine
  • Events
  • Videos
  • Electric Vehicles
  • Consultancy
  • Recent
  • News
    • energy storage
    • Market and Prices
    • Investments & Business
    • Policy and Regulation
  • Articles
    • Batteries
    • Photovoltaic structures
    • Photovoltaic inverters
    • Opinion
  • Renewable
  • Latam
  • Blog
  • Solar Energy Companies
  • Integrators
  • Magazine
    • Magazine Canal Solar
    • Conecta Magazine
  • Events
  • Videos
  • Electric Vehicles
  • Consultancy
  • Recent
  • News
    • Brazil
    • World
    • Technology and inovation
  • Articles
    • technicians
    • Opinion
  • Blog
  • Solar Energy Companies
  • Integrators
  • Magazine
    • Conecta Magazine
  • Events
  • Videos
  • About Us
  • Advertise Here
  • CS Consulting
  • Canal VE
  • Recent
  • News
    • Brazil
    • World
    • Technology and inovation
  • Articles
    • technicians
    • Opinion
  • Blog
  • Solar Energy Companies
  • Integrators
  • Magazine
    • Conecta Magazine
  • Events
  • Videos
  • About Us
  • Advertise Here
  • CS Consulting
  • Canal VE
  • Recent
logo site solar channel
Home / Articles / Coach / Bypass and blocking diode in solar energy systems

Bypass and blocking diode in solar energy systems

Bypass diode and blocking diode fulfill very different functions
Follow on Whatsapp
  • Photo by Hugo Soeiro Moreira Hugo Soeiro Moreira
  • September 8, 2020, at 19:00 PM
6 min 40 sec read

Photovoltaic systems can have two types of diode: bypass diode and blocking diode. Although both are the same device, they fulfill very different functions. The two diodes solve common problems in almost all types of installation.

The bypass diode (also known as the pass diode) aims to prevent the formation of hotspots (hot spots) in photovoltaic modules, while the blocking diode aims to prevent reverse current in strings connected in parallel.

The bypass diode and the hotspot problem

photovoltaic modules They are basically composed of cells connected in series. These modules are also connected in series to form strings.

Therefore, we have a string of hundreds of cells connected in series. This means that, regardless of the shading situation, the current flowing through the cells is the same at all times.

However, when only a portion of the cells in the string are shaded, the short-circuit current level of those shaded cells drops. Any current flowing through a cell at a level above its short-circuit current causes the cell to overheat. This localized overheating (resort of choice.) can permanently damage the cell.

Figure 1 – Hotspot caused by shading from a solar cell. Source: Aerial thermography of photovoltaic plants, Canal Solar, 18/06/2020

To avoid the formation of these hot spots, which damage the cell and permanently compromise the system's performance, bypass diodes are added to the modules during the manufacturing process.

There are usually three or four per module. Each bypass diode is in parallel with a certain number of cells. For example, in 72-cell modules there is a bypass diode for each group of 24 cells.

Figure 2 – 72-cell module with 3 bypass diodes. 24 cells in parallel with each bypass diode [1]
As seen in Figure 2, the bypass diodes are in parallel with a certain number of cells. This sequence of cells in parallel with a bypass diode is like a sub-module.

Under normal conditions, the string current of the solar photovoltaic system flows through the entire module, passing through all cells and through no bypass diode.

If a small number of cells suffer shading and a current greater than that supported by the cell tries to flow, the bypass diode in parallel to that sub-module where the shading occurred is activated, and the current begins to pass through it instead of passing through the submodule.

However, it still flows through the other sub-modules, allowing 2/3 of the original module (in this example) to still continue functioning and generating power normally.

It is important to highlight that in cases of very localized shading, as shown in Figure 1, where only a small number of cells are shadowed, the bypass diode may not come into effect.

As we see in Figure 1, the bypass diode did not act and a cell overheated, detected through thermography (thermal image taken with an infrared light camera).

In most real situations, localized shading is rare or momentary, as the shadow moves over time. Aggressive hotspot situations are more common in cases of dirt or cell defects.

Figure 3 – Current flowing through a module with an activated bypass diode

The blocking diode and the reverse current problem

Reverse current is that which flows in the opposite direction of the photovoltaic module's energy supply. When subjected to reverse current, the solar module stops being a generator and becomes an energy receiver. Although rare, this effect can occur in systems with many strings connected in parallel.

When we have an arrangement with strings in parallel and one of the strings suffers from strong shading or has some defect, the other strings can see the shaded string as a load and inject their current reversely through it. This reverse current permanently damages the photovoltaic module if it exceeds the maximum value specified in the catalog.

Figure 4:- Emergence of reverse current in a shaded string in parallel with other strings operating under perfect conditions

To prevent the modules from being damaged, blocking diodes could be connected, as shown in Figure 5. These diodes aim to ensure that the current only flows in the correct direction, and never in reverse in the modules.

Figure 5 – System immune to reverse current due to the use of blocking diodes

It is important for the reader to understand the operation and function of the blocking diode. For people who are starting to learn about photovoltaic systems, confusion between the blocking diode and the bypass diode is common. They are diodes with completely different functions.

While the bypass diode protects the module against hotspots during its normal operation (that is, when the module is supplying power), the blocking diode is added externally to the module, with the function of protecting it against reverse current.

Although it can be an effective solution against reverse current, the presence of a blocking diode makes photovoltaic installations more expensive and complex.

Furthermore, due to the voltage drop across the diode, these devices cause conduction losses that accompany the photovoltaic system throughout its operating time.

In summary, the blocking diode reduces the overall efficiency of the photovoltaic system and its use should be avoided. Blocking diodes have been replaced by fuses in modern photovoltaic systems.

The stringboxes of photovoltaic systems are equipped with fuses connected in series with each string. In place of a diode blocking the current there is a fuse that can burn if a reverse current occurs.

This solution is cheaper and presents fewer losses, with the only inconvenience of having to replace the fuse when a reversal situation occurs.

Fortunately, these situations are rare and only occur in abnormal situations. To size the fuse against reverse current, the designer must pay attention to the photovoltaic module datasheet.

It is possible to know the maximum reverse current supported or the maximum value of the fuse that should be used. As an example, we have BYD's 360 Wp to 385 Wp monocrystalline family (M6K-36-SERIES-5BB), where the short-circuit current varies from 9,73 A to 9,86 A. And the nominal current value maximum fuse is 15 A.

Figure 6 – BYD M6k-36 modules datasheet from 360 to 385 Wp [3]

References

  • [1] MELO, KB ; MOREIRA, HS ; MOREIRA, AVS; WALLIN, F.; VILLALVA, MG Influence of Backtracking at Solar-Tracking Photovoltaic Power Plants for Generation and Protection. In: 11th International Conference on Applied Energy, 2019, Västerås. 11th International Conference on Applied Energy, 2019
  • [2] MOREIRA, AVS Performance of the Perturb and Observe Method with Adaptive Step and Point Grouping in a Photovoltaic Module with Intelligent Pass Diode in the Face of Partial Shading. Master's Thesis, UFRN, Natal, 2019
  • [3] BYD. MONOCRYSTALLINE M6K-36-SERIES-5BB. Version 1.0.2019. http://www.byd.ind.br/wp-content/uploads/2020/03/M6K_36_SERIE_5BB_pnl_solar_byd_01_0203202.pdf. Accessed on 28/08/2020

Don't miss any news from the electricity sector! Sign up and get exclusive access to our content!

bypass bypass diodes solar energy resort of choice. photovoltaic solar energy systems Photovoltaic systems
Photo by Hugo Soeiro Moreira
Hugo Soeiro Moreira
Technical Manager at DAH Solar. He is a specialist in photovoltaic systems and a PhD and Master's student in electrical engineering at Unicamp. He is dedicated to studying the following topics: module shading, MPPT techniques and power optimizers for photovoltaic generation systems.
PreviousPrevious
NextNext

An answer

  1. EDER ANGELO SOARES said:
    20 from 2021 from September to 11: 11

    Gentlemen, I am studying solar panels and solar generation, but I came across the situation that some companies' energy meters can detect that the customer is generating energy and also charge for what he is generating, for example he is producing 2000w, and the house consuming 1000w, theoretically it is injecting 1000w into the grid but the meter will calculate it as a consumption of 1000w, double loss, could the diode solve this problem of not injecting into the grid? How to solve this case so as not to inject anything? Another question that I don't understand is that it seems to break the wave into half a wave, I don't understand, how to solve this case?

    Reply

Leave a comment Cancel reply

Your email address will not be published. Required fields are marked with *

Comments should be respectful and contribute to a healthy debate. Offensive comments may be removed. The opinions expressed here are those of the authors and do not necessarily reflect the views of the author. Canal Solar.

News from Canal Solar in your Email

Posts

Microgrids: Risen Storage integrating solar energy and battery storage.

Axia Energia expresses interest in investing in energy storage.

Axia Energia, formerly Eletrobras, shows interest in investing in energy storage.

More news

Read More
China leads the energy transition in solar, wind, and electromobility.
  • November 11, 2025
Photo by Daniele Haller
Daniele Haller

China leads the energy transition in solar, wind, and electromobility.

Solar power plant with rows of photovoltaic panels, showing what large-scale solar energy is and its role in the Brazilian electricity grid.
  • November 10, 2025
Editorial Photo Canal Solar
Redação Canal Solar

What is solar energy? See the complete guide on the subject.

Australia: Three hours of free solar electricity starting in 2026
  • November 7, 2025
Photo by Daniele Haller
Daniele Haller

Australia: Three hours of free solar electricity starting in 2026

It is a news and information channel about the photovoltaic solar energy sector. Channel content is protected by copyright law. Partial or total reproduction of this website in any medium is prohibited.

Facebook X-twitter Instagram Youtube LinkedIn Spotify

Site Map

Categories

  • News
  • Articles
  • Interviews
  • Consumer Guide
  • Authors
  • Projects
  • Brazil
  • World
  • Technical Articles
  • Opinion Articles
  • Manufacturer Items
  • Electrical Sector
  • Biddings
  • Products

Channels

  • About Us
  • Contact
  • We’re hiring!
  • Privacy
  • Expedient
  • advertise here

Membership and certifications

Copyright © 2025 Canal Solar, all rights reserved. CNPJ: 29.768.006/0001-95 Address: José Maurício Building – Mackenzie Avenue, 1835 – Floor 3, – Vila Brandina, Campinas – SP, 13092-523

We use cookies to make your experience on this site better Find out more about the cookies we use or turn them off in your .

Receive the latest news

Subscribe to our weekly newsletter

Canal Solar
Powered by  GDPR Cookie Compliance
Privacy

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognizing you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.

Cookies strictly required

Strictly Necessary Cookie should be at all times so that we can save your preferences for cookie settings.

Cookies for third parties

This website uses Google Analytics to collect anonymous information such as the number of visitors to the site, and the most popular pages.

Keeping this cookie enabled helps us to improve our website.