Compatibility between bifacial photovoltaic modules and optimizers

This article addresses the compatibility of bifacial solar panels with optimizers
Compatibilidade entre módulos fotovoltaicos bifaciais e otimizadores

With the emergence of bifacial photovoltaic modules on the market, many users question their compatibility with inverters, microinverters and power optimizers.

First of all, what is a power optimizer? If you have reached this article and are still unfamiliar with the subject, I recommend reading two articles:

Power Optimizer

The power optimizer is a small device connected to the output of the photovoltaic module. Due to its dimensions, and also practicality, the optimizer is physically housed behind the module, attached to the fixing structure or the frame of the module itself.

The function of the optimizer, as its name suggests, is to optimize the energy generation of the photovoltaic module. This is done through the individualization of the MPPT (maximum power point tracking) of each of the modules that make up the photovoltaic system.

Thus, the modules are decoupled and make the photovoltaic system practically immune to shadows. There are still other advantages. Even in situations without shading, the optimizers reduce the so-called power “mismatch”, which is the discrepancy between the powers of the modules connected in series.

Typically the gain obtained with mismatch reduction is around 2%. It seems small, but over the lifetime of the photovoltaic system this can represent a large amount of energy.

O otimizador de potência é ligado à saída do módulo fotovoltaico e alojado fisicamente sob o módulo, podendo ser preso à estrutura ou à moldura do próprio módulo
Figure 1: The power optimizer is connected to the output of the photovoltaic module and physically housed under the module, and can be attached to the structure or frame of the module itself

In addition to the issue of shadows and power mismatch, there is another advantage to using optimizers.

With them it is possible to form strings of modules installed in different positions, subject to different solar irradiation and very different operating conditions. This would be impossible with traditional inverters.

On complex roofs or urban installations subject to a lot of shading from nearby objects, the optimizer is a good choice for solar PV design.

Otimizadores permitem a formação de strings com módulos sob condições operacionais muito distintas
Figure 2: Optimizers allow the formation of strings with modules under very different operating conditions

And bifacial photovoltaic modules, what can we say about them? As the name suggests, they are modules that have two sides.

Bifacial photovoltaic modules capture light through the front and rear surfaces, and can have higher power and generation than conventional modules, depending on the amount of light reflected in the location.

Bifacial solar panels are most useful in solar plants, where the module is distanced from the ground, allowing the rear surface to capture a large amount of light reflected from the ground.

On roofs, bifacial modules may have some performance increase in installations with metal tiles or, mainly, in structures inclined on slabs.

In the following tables we find the electrical characteristics of bifacial modules from the manufacturer Risen Energy, with nominal peak powers from 435 W to 455 W. Every photovoltaic module is specified in STC conditions (25 oC and 1000 W/m2).

Traditional solar panels will always perform at or below that shown in the STC table in the datasheet.

Bifacial photovoltaic modules, because of the additional capture of light reflected from the ground, can have a “bifaciality gain”, whereby the operating power, current and voltage will be greater than those specified in the STC characteristics table.

This means that a module with a nominal power of 450 W can, in practice, operate as a 585 W module if we consider a bifaciality gain of 30%, as the following table demonstrates.

Electrical characteristics tables for Risen RSM144-7-435BMDG-455BMDG modules

Tabela

The question of compatibility

With the gain of bifaciality, the electrical characteristics of photovoltaic modules are increased, as we mentioned above. This requires special care when specifying other components of photovoltaic systems, including power optimizers.

SolarEdge, the leading manufacturer of power optimizers, issued the technical note “Application Note – Compatibility of bi-facial modules with SolarEdge power optimizers” in January 2020, which describes the correct method for selecting power optimizers for use with bifacial modules .

The correct selection of the optimizer depends on the electrical characteristics of a given module. When designing a solar system with bi-facial modules, it is challenging to estimate the generation gain added by the back of the modules, especially due to the non-uniformity nature of the irradiance reflected from the ground.

The gain of reflected light is highly influenced by various conditions such as geographic location, temperature, tilt of the modules, surface area behind the modules, and so on.

In order to provide design flexibility and support for a range of modules, SolarEdge power optimizers include a feature that is capable of handling the wide range of current and power expected from a bifacial module, even in extreme cases like those mentioned above .

When using bifacial modules, SolarEdge allows you to select optimizers that support the maximum power, current and voltage of the modules, considering the front electrical values (in STC) informed in the modules' data sheet.

It is important to note that the optimizer warranty may be void if the power, voltage or current of the selected module in STC (without considering bifaciality gain) is above the specifications of the selected optimizers.

When designing a system (manually or using a sizing tool) it is important to always make the optimizer characteristics compatible with the output characteristics of the photovoltaic module in STC declared in the module data sheet, without considering the power gain caused by nature. bifacial module.

In other words, you must design the system as you have always designed it, even though the module in practice may exceed the rated power, current, or voltage values due to the collection of reflected light.

Optimizers will be prepared to deal with the bifaciality gain as long as the optimizer choice is made according to this basic guideline.

Sizing example

Bifacial Module Specifications

  • Power in STC (with 0% bifacial gain): 400 W;
  • Power in STC (with bifacial 30%): 520 W;
  • Open circuit voltage at STC: 49.7 V;
  • Short-circuit current in STC: 10.22A;
  • Current thermal coefficient: 0.03 [%/°C];
  • VOC stress thermal coefficient: -0.27 [%/°C].

Optimizer to be selected (considering two modules in series)

  • Model (family): P850-4xxxxxx, serial number SJ5019A-xxxxxxxx;
  • Maximum power = 850 W (greater than 2 x 400 W = 800 W);
  • Maximum input voltage = 125 VDC (greater than 2 x 49.7 V = 99.4 V);
  • Maximum input current = 12.5 ACC (greater than 10.22 A).

Selected inverter

  • Output power (AC): 25 kW.

Design considerations

  • Maximum string power: 15.75 kW (for a 230 V to 400 V network);
  • Maximum input power (DC) of the inverter in STC (135% oversizing): 33.75 kW;
  • Maximum number of modules in the string: 15.75 kW / 400 W = 39 (20 power optimizers);
  • Maximum number of modules connected to the inverter: 33,750 kW / 400 W = 84 (42 power optimizers).

Note: The example above was taken from the document “Application Note – Compatibility of bi-facial modules with SolarEdge power optimizers”.

Consult your local supplier to check the availability in Brazil of the models mentioned in the example and to check the compatibility of other models.

Conclusion

The power gain provided by bifacial modules can typically reach 30% over the nominal power value of the module.

When sizing a bifacial module project with power optimizers, it is important to initially ensure that the optimizer's characteristics match the characteristics of the photovoltaic module in STC informed in the catalog (without considering the bifaciality gain).

This basic rule guarantees the integrity of the project and prevents loss of the optimizer's warranty. Following the basic rule, as shown in the exemplified case study, the optimizer is sized with a slight power gap.

The same occurs with the total power of the inverter, which in this example was sized 35% above the nominal power of the modules in STC.


Picture of Marcelo Villalva
Marcelo Villalva
Specialist in photovoltaic systems. Professor and researcher at the Faculty of Electrical and Computer Engineering (FEEC) at UNICAMP. Coordinator of LESF - Energy and Photovoltaic Systems Laboratory at UNICAMP. Author of the book "Photovoltaic Solar Energy - Concepts and Applications".

3 Responses

  1. Good morning! I don't understand one question: If the inverter selected was 25 kW, and at its input 35% is above its capacity (which is that of the modules), then it has no power gap, as stated… Could you clarify? Thanks.

  2. When we talk about bi-facial modules, I think it is important to make it very clear that they are a technology designed specifically for soil plants. As suggested in the article, they could even be used on slabs or metal roofs that have inclination correction, but knowing the reality of installations in our country, correcting inclination on roofs, in the vast majority of cases, does not make much sense.

Leave a Reply

Your email address will not be published. Required fields are marked *

Receive the latest news

Subscribe to our weekly newsletter