Find out the real risks of fires in photovoltaic systems

Find out what are the main risks that can cause fires in photovoltaic equipment

Author Mateus Badra
Published 14 May 2020, 07: 31 Updated 31 May 2024, 05: 40
Reading 10 min read
Share Canal on WhatsApp

Photovoltaic installations, like any electrical installation, are subject to equipment and installation failures that can cause fires.

However, given its relatively new introduction into the market, the reasons for equipment, design and installation failures that can lead to accidents are not yet fully understood either by the end customer or by most professionals in the sector.

It is recognized that the main point of failure in photovoltaic systems is poor quality connections of the direct current part of the system [1], and that these are caused by electric arcs.

However, failures in other components of the installation still represent around 20% of the causes that lead to fire [2].

To fully understand the risks, a complete system analysis is necessary, which will be the topic of this article.

One point that should be noted is that photovoltaic solar systems are safe when designed and executed by trained professionals.

Overview of photovoltaic systems

Germany was the first country to develop a large number of photovoltaic systems, thus having a good percentage of systems with ten years or more of installation. Therefore, there is a wealth of data on the medium and long-term behavior of failures in PV systems.

Studies of fires in installations where there were photovoltaic systems [1] show that 56% of fire cases occurred due to lightning strikes and, of the remaining 44%, 17% of fires were caused by product failure, 9% by design errors and 18% due to installation failures.

Compared to the total number of photovoltaic installations in Germany (1,3 million) only 0,016% of installations suffered failures that led to fires. The annual number of fires of electrical origin in the country [3] is 18 thousand cases, far below the number of fires due to the photovoltaic system.

Figure 1: Main failures that lead to fire in photovoltaic systems. Source: Sepanski et. al
Figure 1: Main failures that lead to fire in photovoltaic systems. Source: Sepanski et. al

Of the internal failures, that is, the failures that were not caused by external events such as lightning, we have the following breakdown of the distribution of failures: 51% caused by installation errors, 19% caused by errors in the DC circuit, 12% by internal failures of modules, 10% of failures internal to the inverter and 8% due to failures in the AC circuit.

Figure 2: Distribution of failures that led to fire in photovoltaic systems. Source: Sepanski et. al. 2015
Figure 2: Distribution of failures that led to fire in photovoltaic systems. Source: Sepanski et. al. 2015

Failure analysis

The electrical arc is the main component failure mechanism that causes fires in systems [1]. The sources of failure are detailed in the tables below according to the probability of occurrence.

It is noted that failures are mostly dependent on the quality of the installation.

Table 1: Faults causing electric arcs, ordered by probability of occurrence
20200514 solar channel fv fire analysis tab1

DC Connectors

Electrical arcs in connectors are mainly caused by installation faults. To ensure correct fitting, it is necessary to follow the recommendations for the maximum size of the bare wire that fits into the terminal and also the correct use of a tool to terminate the conductor.

The use of incorrect termination pliers is the main cause of this type of connection failure [2]. The figure below illustrates the difference in termination quality for two types of pliers.

Figure 3: Using the correct tool significantly increases the pullout resistance and durability of the connection
Figure 3: Using the correct tool significantly increases the pullout resistance and durability of the connection

It is also common to find errors in the plastic cover that tightens the rubber seal. This type of error causes the ingress of water and pollutants, causing the connection to deteriorate, heat up and lose protection against electrical arcs.

Figure 4: Exploded view of the MC4 connector. To guarantee ideal isolation, it is necessary to respect the assembly order and the tightening torque at the bottom of the connector.
Figure 4: Exploded view of the MC4 connector. To guarantee ideal isolation, it is necessary to respect the assembly order and the tightening torque at the bottom of the connector.
Figure 5: Fault found during the commissioning stage of a system. The plastic bottom of the connector must be put on before terminating the connection. In the figure, the bottom of the connector has been mistakenly replaced with electrical tape
Figure 5: Fault found during the commissioning stage of a system. The plastic bottom of the connector must be put on before terminating the connection. In the figure, the bottom of the connector has been mistakenly replaced with electrical tape

Connectors from different models and manufacturers should also not be used in the same connection, as perfect electrical fit and insulation of the male-female pair cannot be guaranteed.

The standards for Brazilian and international photovoltaic installations themselves (NBR 16690 and IEC/TS 62548) clearly mention this issue.

Each manufacturer uses a different material, which can cause chemical incompatibility (contact corrosion) and mechanical incompatibility (different designs and thermal expansion), for example.

The use of different connectors can increase contact resistance, which in turn increases the internal temperature of the connector, which can reduce its useful life or even cause it to melt.

Figure 6: Connector mismatching can significantly increase contact resistance and connection temperature
Figure 6: Connector mismatching can significantly increase contact resistance and connection temperature

Excessive or insufficient application of torque to the termination of the MC4 type connector or to the device screws can also cause high contact resistance or connection failures, as already discussed in the article on electric arcs that we published here on Canal Solar.

photovoltaic modules

The main fire mechanisms in photovoltaic modules are related to reverse current, module quality and the presence of microcracks.

The reverse current, already covered in our article “Causes and effects of reverse current in photovoltaic modules” is a failure situation where series in parallel have different Voc (open circuit) voltages, either due to an internal module failure (internal short circuit) or due to a design and installation error.

When the condition for harmful reverse current arises (two or more series in parallel with a series of distinct Voc), if the system is not protected by a fuse, the module will heat up, which now behaves like a reverse biased diode and may become a fire source.

Figure 7: Damaging reverse current occurs when there is a voltage difference Voc between strings in parallel
Figure 7: Damaging reverse current occurs when there is a voltage difference Voc between strings in parallel

The low quality of the modules can also cause accidents. Problems such as poorly done soldering, poor and poorly designed packaging, lack of care during transportation and installation can cause the module's internal conductors to weaken or break. When this occurs, an internal electrical arc and, eventually, a fire may also occur.

Figure 8: Damaged internal module tracks can also become sources of series arc flashes
Figure 8: Damaged internal module tracks can also become sources of series arc flashes

Microcracks caused by impacts or stepping on the modules, in addition to reducing the module's power, also pose a risk, since their cracks contain high electrical resistance that also causes heating. The figure below illustrates the increase in temperature caused by microcracks.

Figure 9: Microcracks cause localized heating of the module, which in turn reduces its power and useful life
Figure 9: Microcracks cause localized heating of the module, which in turn reduces its power and useful life

string box

Special care must be taken in the string box. Failure to apply the correct torque to the screws, the use of incorrect connections and box sealing problems are directly associated with the risk of electrical arcs and internal short circuits.

As for the components, it is essential that they respect the temperature, voltage, insulation and current limits for which they were designed. The technical specification of each of the string box components can be found in the article Understand the basic specifications of the String Box components.

It is mandatory that all external string boxes have a protection level of at least IP55. In a recent article, DPS: The airbag of photovoltaic systems, it becomes clear how the lack of internal quality of a component that was apparently correctly sized can cause a serious electrical failure.

Table 2: IP classification of protection against the ingress of solid and liquid bodies

20200514 solar channel fv fire analysis tab2

Figure 10: The low-quality DPS caused an arc during its performance, which led to its melting
Figure 10: The low-quality DPS caused an arc during its performance, which led to its melting
Figure 11: You should not parallelize cables in devices that are not suitable for this purpose. Connection termination also becomes mandatory
Figure 11: You should not parallelize cables in devices that are not suitable for this purpose. Connection termination also becomes mandatory

Inverter and AC Installation

The inverter itself, especially when from a good quality manufacturer, presents little risk of internal arcing, precisely because it has a robust design and internal protections that can detect faults early.

Electrical defects in inverters are mostly due to [1] design and installation: terminals that are poorly crimped or have the wrong conductors and voltage and current limits that are higher than permitted.

The conditions of the installation location must also be observed: the NBR 5410 standard classifies environments and buildings according to their risk of combustion and gives guidelines on the level of protection of devices and conductors that can be used.

The sizing of AC and DC cables, according to current-carrying capacity criteria, is also directly related to the risk of heating and melting. For more information on sizing, read the article Sizing of cables and protections in photovoltaic systems.

Figure 13: The improvisation of an output box caused the metal burrs to cut the string conductors
Figure 13: The improvisation of an output box caused the metal burrs to cut the string conductors

Fault and fire prevention

Based on the fire studies shown previously, we can classify the main actions for preventing failures between design actions, installation actions and component selection actions.

Table 3: Actions to prevent failures and fires in photovoltaic systems

20200514 solar channel fv fire analysis tab3

The Brazilian standard ABNT NBR 16274 dictates which commissioning tests must be carried out at the end of the installation, thus complementing fire prevention. This standard will be the subject of a future article here on Canal Solar.

Conclusion

Installing a photovoltaic system does not increase the risk of fire in an establishment. In a more mature market, such as Germany, only 0,016% of electrical fires were due to photovoltaic system failures.

Due to the growth of the solar energy market and the increase in the presence of new designers and installers, the technical training of professionals and the choice of good components are essential for fire prevention and the maturation of the national photovoltaic market.

A good choice of equipment is not limited only to its performance. When choosing equipment, it is important to consider the manufacturer's presence in the national market.

As the majority of failures are due to installation problems, good technical support and the provision of training by these manufacturers strengthen and mature the installations of market professionals.

References

  • [1] Sepanski et. al., 2015. Assessing Fire Risks in Photovoltaic Systems and Developing Safety Concepts for Risk Minimization
  • [2] PV bankability analysis, Stäubli
  • [3] Consumer fire safety: European statistics and potential fire safety measures
  • [4] World Fire Statistics 2018, International Association of Fire and Rescue Services


fire fire in photovoltaic systems protection Safety Photovoltaic systems
Mateus Badra
About the Author
Mateus Badra

Journalist graduated from PUC-Campinas. He worked as a producer, reporter and presenter on TV Bandeirantes and Metro Jornal. He has been following the Brazilian electricity sector since 2020.

Comments (3)

Comments are moderated before publication.

Comments should be respectful and contribute to a healthy debate. Offensive comments may be removed. The opinions expressed here are those of the authors and do not necessarily reflect the views of the author. Canal Solar.

Leave your comment Cancel reply

  • Orlando 29/09/2022 · 18:15

    Congratulations on the article!
    What suggestions would you give to prevent electrical damage or defects in the system and panels? In this case, those that may require repairs to the photovoltaic panel support brackets. If they require the electrical welding process on the structure using a coated electrode, of course, preserving the mechanical integrity of the panels and other components of the photovoltaic system? Thank you! Orlando Moreira.

    Reply
    • Eduardo Bueno 30/11/2022 · 16:24

      Hello, Orlando, how are you? One of the essential practices for the proper functioning of the PV system is cleaning the modules, so that there is no obstruction in the “path” between solar rays and the module cells, and carrying out commissioning tests (carried out by trained professionals) to check connections and protections, and also to check the energy generation produced

    • Edmar Ribeiro 10/10/2023 · 18:39

      How do commissioned tests work? Is there a report that attests to the safety of solar panels?

Posts

Canal Solar - YOU.ON obtains BNDES accreditation to compete in auction for batteries with national content.
Market & Investments

YOU.ON obtains accreditation from BNDES to participate in the auction for batteries with national content.

Henrique Hein · Oct 23
Canal Solar - The electricity sector will grow and be sustainable for several years to come, not only in Brazil, says Hitachi director.
Market & Investments

"The electricity sector will grow and be sustainable for several years to come, not only in Brazil," says Hitachi's director.

Antonio Carlos Sil · Oct 23
The second round of elections mobilizes distributors to guarantee energy supply.
Market & Investments

The second round of elections mobilizes distributors to guarantee energy supply.

Caique Amorim · Oct 22
Canal Solar - BNDES will now finance 100% of battery projects that meet national manufacturing criteria.
Market & Investments

Battery projects with domestic manufacturing receive up to 100% financing from BNDES.

Henrique Hein · Oct 22

Most Read

01

Check out the ranking of the 10 largest energy consumers in the world

Brazil ranks eighth on the list with 509 TWh, according to Worldometer

02

Solar energy certification: what is it, when and how to do it?

Find out why this process is essential and how to carry it out simply and efficiently

03

Battery for solar system: understand if it is worth installing

Learn about the different types of batteries, backup applications and benefits

04

The power went out during voting: will the electronic voting machine still work?

The devices have internal batteries with a runtime of approximately 12 hours; four models will be used this year.

05

Saving cables with leap-frog connection of photovoltaic modules

Understand the leap-frog strategy and learn how it allows you to reduce the cost of electrical cables in facilities

Categories

Market & InvestmentsInternational marketPolitics & RegulationProjects & ApplicationsSustainability & ESGTechnology & Innovation

Receive the news in your email.

Daily bulletin with the essentials of the solar sector.

✓ Registration confirmed!
Share
Canal Solar

This is a news and information channel about the photovoltaic solar energy sector. The content is protected by copyright law.

Categories
  • Market & Investments
  • International market
  • Politics & Regulation
  • Projects & Applications
  • Sustainability & ESG
  • Technology & Innovation
Institutional
  • About Us
  • Contact
  • Privacy
  • Quality policy
  • We’re hiring!
Place your ad

Your brand where energy sector decisions happen.

Download media kit
Group Canal Solar
Canal Solar EducationalCS ConsultingCanalVE
Associations and certifications
ABGDIEEECIGRÉCREA-SPABSOLAR Associate
Copyright © 2026 Canal Solar. All rights reserved. CNPJ: 29.768.006/0001-95 Developed by Softeo Technology
GDPR Cookie Banner

We use cookies to make your experience on this site better Find out more about the cookies we use or turn them off in your .

Canal Solar
Powered by  GDPR Cookie Compliance (opens in a new tab)
Privacy

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognizing you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.

Cookies strictly required

Strictly Necessary Cookie should be at all times so that we can save your preferences for cookie settings.

Cookies for third parties

This website uses Google Analytics to collect anonymous information such as the number of visitors to the site, and the most popular pages.

Keeping this cookie enabled helps us to improve our website.