This article shows that inverters with more than one MPPT input can be operated with a single input, even when their datasheet (datasheet) states that they physically have two or more MPPT inputs. MPPT is the acronym for maximum power point monitoring (maximum power point tracking), which is a feature built into all inverters for use in grid-connected photovoltaic systems. This feature is important to ensure the operation of photovoltaic modules always at the point of maximum power, enabling maximum energy generation by the photovoltaic system. Recently, inverters with two or more MPPT inputs have become common on the market. This means that modules connected to one input are decoupled from modules on other inputs. The inverters perform maximum power tracking separately for each input, allowing the modules of a project to be divided into independent groups. This is useful when we have projects with shadows or roofs with different slopes and orientations, for example. In some cases, however, we see inverters with multiple MPPT inputs being sold in photovoltaic generator kits with just one stringbox. How is this possible? In theory, if there are two MPPT inputs and if there is a need to use stringbox, two should be used stringboxes, one for each entry. This is true, but not always. It depends on how the inverter is being configured, as we will explain in this article. The important fact that we want to highlight in this article is that inverters with more than one MPPT input can have all of their inputs connected together, starting to function as single-input inverters. The advantage of this is that, in many cases, there is no need for independent MPPT inputs and connecting to a single input makes installation simpler and cheaper. In summary, even if the inverter offers two or more inputs, it still offers the possibility of working with a single input. When we analyze inverter data sheets we see in their descriptions the number of MPPT inputs that the equipment has. Typically, inverters sold in the micro and minigeneration market have between two and four inputs. Below we find, for example, the REFUone 3K-2T model from Refusol. This 3 kW inverter has 2 independent MPPT inputs and allows you to connect one string by MPPT.

Specifications table found in the Refusol inverters datasheet:


In rarer cases, it is possible to find a system like the one illustrated in the following figure, in which the parallelism of the MPPT inputs is carried out outside the inverter. In this case, the stringbox must be designed appropriately. In the example below we have a system that has only 1 string and we want to connect this string to an inverter that has 2 MPPT inputs. This is technically possible as long as the manufacturer allows it and as long as the inverter is configured to operate in this way, as we will see in the case study shown in the next section of this article. In the diagram below, we see that the stringbox It has only one input and two outputs. Each output is connected to an inverter input connection and within the stringbox the two outputs are connected in parallel.
Parallelism of MPPT inputs carried out in the stringbox.
Case study
This study is based on a generator sold by Aldo Solar. It is made up of 8 335 W photovoltaic modules and a 3 kW Refusol inverter. The supplier itself has some instructions on its website for installing this system by joining the two inputs, as seen below, highlighting that the two pairs of cables (2 positive and 2 negative) must have the same length and the same gauge in this project. in particular, since the output current of the stringbox must be shared between the two inverter input connections.

Table with data from the 1E-2S stringbox (1 input and 2 outputs) sold together with the REFUone 3K-2T inverter for use with 2 MPPT inputs connected in parallel:

The generator kit in question is being supplied with the inverter configured in parallel mode and, therefore, this connection possibility is possible, that is, the inverter physically has 2 MPPT inputs, but this function is not being used in this system. The figure below, taken from the inverter manual, shows that the two inputs strings are linked to a single “boost” block. In other words, the inverter operates with a single MPPT, with two strings connected in parallel at the equipment input.

Conclusion
Inverters for grid-connected photovoltaic systems may have one or more MPPT inputs, depending on the model. The number of available inputs is specified in the product data sheet. Under specific conditions, the use of multiple inputs is not necessary. Some equipment allows MPPT inputs to be grouped into a single input. If the equipment is marketed and intended to be used in this way, the design of the photovoltaic system must take this into account.



Comments (3)
Comments are moderated before publication.Comments should be respectful and contribute to a healthy debate. Offensive comments may be removed. The opinions expressed here are those of the authors and do not necessarily reflect the views of the author. Canal Solar.
I WANT TO WORK WITH SOLAR ENERGY PROJECTS IN THE AREA OF MICROGENERATION AND MINIGENERATION PLANT
Dear, how are you?
I'm having trouble with this MPPT issue. Let's say I have a Sungrow SG250HX. The datasheet says that each MPPT input supports 26 A, and that it has 12 MPPTs. In this case, if I want to use a single input, would I multiply 26 by 12 to find out the maximum input current?
I have an installation with a Solis 75kW 5G inverter. It has 9 MPPTs in 18 inputs. Would there be any problem using the maximum capacity of the inverter using 7 MPPTs? The biggest issue would be economic viability, with fewer strings and less cabling.