Understanding the IV and PV curves of photovoltaic modules

Understand the characteristics of photovoltaic modules through IV and PV curves

Understanding the IV and PV curves of photovoltaic modules

This article aims to clarify the characteristics of photovoltaic modules through IV and PV curves.

Curve IV is the graph that relates the current (I) and the output voltage (V) of the photovoltaic module.

Already PV curve is the graph that relates the power (P) and the voltage (V) module output.

A isc (short circuit – short circuit current) is the maximum electrical current that the module can provide.

O You (open circuit – open circuit voltage) is the maximum tension that the module can provide.

A Imp (maximum power – maximum power current) is the current that the module provides when operating on its maximum power point.

A vmp (maximum power voltage) is the voltage that the module displays on its terminals when operating in its maximum power point.

A Pmp (maximum power output) the name is a bit redundant and means exactly that. In other words, this is the peak power of the photovoltaic module.

A MPP (maximum power point) is the maximum power point of the photovoltaic module. It lies at the knee of the IV curve and the peak of the PV curve.

The values ​​of Isc, Voc, Imp, Vmp, Pmp are specified in the data sheets for a irradiance of 1000 W/m² and an operating temperature of 25 °C.

The figures below illustrate how the Isc and Voc parameters are measured. The short-circuit current Isc is measured with a ammeter, short-circuiting the output terminals of the photovoltaic module.

During the test illustrated in the figure below, the module is short-circuited internally by the multimeter (operating in ammeter mode).

The open circuit voltage Voc, in turn, is measured with a multimeter operating in voltmeter mode, keeping the photovoltaic module terminals open.

Although they are connected to the multimeter during the test, there is no current passing through the module's output terminals, therefore we say that it is open circuit (off).

Figure 1: Measurement of the module's short-circuit current with a multimeter (in ammeter mode)
Figure 1 – Measurement of the module’s short-circuit current with a multimeter (in ammeter mode)
Figure 2: Measurement of the open circuit voltage of the photovoltaic module with a multimeter (in voltmeter mode)
Figure 2 – Measurement of the open circuit voltage of the photovoltaic module with a multimeter (in voltmeter mode)
Marcelo Villalva
About the Author
Marcelo Villalva

Specialist in photovoltaic systems. Professor and researcher at the Faculty of Electrical and Computer Engineering (FEEC) at UNICAMP. Coordinator of LESF - Energy and Photovoltaic Systems Laboratory at UNICAMP. Author of the book "Photovoltaic Solar Energy - Concepts and Applications".

Comments (5)

Comments are moderated before publication.

Comments should be respectful and contribute to a healthy debate. Offensive comments may be removed. The opinions expressed here are those of the authors and do not necessarily reflect the views of the author. Canal Solar.

Leave your comment

Canal Solar
Privacy

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognizing you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.