GC Solar 23.61 GW GD Solar 53.65 GW
Technical Article

How do you know if a photovoltaic module is real?

Most consumers will never realize that they have installed “counterfeit” modules on their roof

Canal Solar How to know if a photovoltaic module is genuine

Large consumers are already carrying out tests in the field or in the laboratory to be sure of what they are buying. Photo: PVEL

Article published in the 16st edition of the Magazine Canal Solar

News of counterfeit photovoltaic modules has been circulating on the market. Regardless of the veracity of this news, it is a fact that there are modules on the market being sold with lower power than that specified on the label.

In other words, the modules are true, but the labels present false information. Perhaps this is the biggest fake on the market. This is more common than you might think, but only now are consumers and distributors beginning to realize this problem.

In our laboratory at Unicamp we frequently receive photovoltaic modules from distributors interested in confirming the characteristics of their imported products. Fortunately, we often confirm that the products are good.

On the other hand, unfortunately, we have already detected several samples of products with specifications lower than those shown on the labels. To speak in simple language, for example: the product is sold with a 550 W label, but it is actually a 500 W module.

Companies ask us to keep the results confidential and, furthermore, we cannot disclose the results because whenever a manufacturer has its quality challenged, the first thing it does is question the quality of the tests carried out in Brazil, suggesting that our equipment is out of calibration. .

Most consumers will never realize that they have installed “counterfeit” modules on their roof. However, large consumers are already carrying out tests in the field or in the laboratory to be sure of what they are buying.

Builders or owners of distributed or centralized generation plants can carry out testing of photovoltaic modules by sampling, both in the laboratory and in the field.

field tests

Two tests can be carried out at the installation site, where the modules are unloaded: the IV curve test and the electroluminescence test.

Photovoltaic system integrators generally do not have IV curve tracers, due to the high cost of the equipment. The equipment for electroluminescence testing is even more expensive and this procedure is unfeasible in micro and mini generation systems.

Even when an IV curve tracer is available, IV curve testing is always done on strings and never on individual modules. In other words: it is very difficult, whether due to lack of equipment or operational difficulties, to investigate all the modules of an installation.

Normally, when you want to test modules individually (and not within strings), this type of test is done on a small number of samples from the same batch, which may be enough to detect anomalies.

The IV curve test has better accuracy when carried out in the laboratory, but it is recommended to carry it out in the field whenever possible. This test is performed with a portable tracer, as shown in Figure 1.

Figure 1: Portable IV curve tracer. Source: LESF/UNICAMP

The second test we can do in the field is electroluminescence (EL). This is more difficult, as it needs to be done at night and requires the photovoltaic module to be energized, which poses a certain technical challenge, as an electrical power generator needs to be available at the test location.


The opinions and information expressed are the sole responsibility of the author and do not necessarily represent the official position of the author. Canal Solar.

Marcelo Villalva
About the Author
Marcelo Villalva

Specialist in photovoltaic systems. Professor and researcher at the Faculty of Electrical and Computer Engineering (FEEC) at UNICAMP. Coordinator of LESF - Energy and Photovoltaic Systems Laboratory at UNICAMP. Author of the book "Photovoltaic Solar Energy - Concepts and Applications".

Comments (8)

Comments are moderated before publication.

Comments should be respectful and contribute to a healthy debate. Offensive comments may be removed. The opinions expressed here are those of the authors and do not necessarily reflect the views of the author. Canal Solar.

Leave your comment

  • Helcio Caiafa Rachid

    Professor Marcelo.
    I have a 75 Kw power plant, there are 250 445Wp panels, with 112,14Kwp of power, they are all blue in specific points and/or throughout.
    I made a big investment and I'm very worried about the situation.
    I have another 37 Kw plant with 550 Kw plates, the plates did not show anything, the manufacturer is Amerisolar.
    If possible, I would like to exchange some ideas about this, I have a warranty but the representative here in Belo Horizonte gave me a 2-year warranty on the boards but is talking to Amerisolar in China.

  • Edilson Elias

    Firstly, I would like to say that I really enjoyed the article, the content is very interesting and useful for those who work in the field and for those who don't.
    I believe that this explanation about possible tests will be very useful for me and for others. I live outside of Brazil and the counterfeiting of electrical and electronic devices is something “normalized” in my country, so knowing how to check the originality of photovoltaic panels will be a very good practice for me.

  • Francisco son

    Of course, everything has to be done clearly and truthfully for everyone.
    We need to put an end to so many frauds and mistakes, no more being harmed day in and day out.

  • Flávio Nunes

    The news headline is interesting, but in practice it does not help, as it is described that the tests are highly difficult to carry out.

  • Laertius

    Because UNICAMP is public, it cannot afford to stop this waste and fail to publicize a fraud that harms the consumer, this is, at the very least, criminal.

  • Danilo Araujo

    Some inverters already have the IV curve function incorporated, making analysis easier!

Canal Solar
Privacy

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognizing you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.