GC Solar 23.61 GW GD Solar 53.65 GW
Canal Solar
  • HOME
  • Latest News
    • Market & Investments
    • International market
    • Politics & Regulation
    • Projects & Applications
    • Sustainability & ESG
    • Technology & Innovation
  • Articles
    • Opinion Article
    • Technical Article
    • Manufacturer's Article
  • Latam
  • Consumer Guide
  • Business Directory
  • Magazine
  • Videos
  • Electric Vehicles
  • Firmare
Solar Energy Courses
  1. Home
  2. Technical Article
  3. Functions and technical requirements of photovoltaic inverters
Technical Article

Functions and technical requirements of photovoltaic inverters

Learn more about the functions of photovoltaic inverters and how they can be efficient

Author Marcelo Villalva
Published 9 2019 December, 22: 25 Updated September 26, 2024, 10:55 pm
Reading 10 min read
Share Canal on WhatsApp
Functions and technical requirements of photovoltaic inverters

See some basic functions and characteristics of inverters

Inverters have functions that are desirable and necessary to operate with photovoltaic systems, while other functions and some requirements are required by standard.

When we talk about technical requirements for inverters, the first reference we should consult is the standard NBR 16149: Photovoltaic (PV) Systems – Connection interface characteristics with the electrical distribution network.

This standard, as its name suggests, determines how photovoltaic inverters must behave when interacting with the low voltage electrical grid.

Tip: find the original standards at an affordable cost on the website target.com.br

In Brazil, in order to connect to the electrical grid, photovoltaic inverters up to 10 kW must comply, in addition to NBR 16149, with standards NBR 16150 and NBR 62116.

We will talk about standards in the next articles in the series, while we will focus in this article on some basic functions and characteristics of inverters.

Basic functions of inverters

Output current control

Photovoltaic inverters for grid connection (grid-tie) are electronic current sources. This means that these inverters do not supply electrical voltage at their terminals, like conventional DC-AC inverters. A grid-tie inverter is not capable of powering any type of load on its own, and must always be connected to the electrical grid in order to operate.

What does it mean to be connected to the electrical grid? It means that the inverter receives the mains voltage at its terminals (127 V, 220 V, etc.) and uses this voltage as a reference for its operation.

Once connected to the grid, the inverter has the primary function of producing a sinusoidal electrical current at its output terminals, synchronized with the grid voltage waveform, with the aim of injecting energy extracted from the solar panels into the grid.

This energy can be consumed instantly by nearby loads or can be exported to the energy distribution company, if consumption at the injection point is lower than generation.

Functions and technical requirements of photovoltaic inverters
Figure 1 – The grid-tie inverter produces a sinusoidal electrical current at its output terminals in synchronization with the electrical grid voltage

Input voltage control

The grid-tie inverter has an unusual feature, not found in other types of inverters: its input voltage is controlled. This is necessary to allow operation with voltage values ​​that can be adjusted according to the type and number of photovoltaic modules connected to the inverter input.

Furthermore, this function is important because photovoltaic modules have variable output voltage. The modules, without the aid of an inverter, are unable to stabilize their output voltage. Photovoltaic modules in isolation are not useful for powering any type of load, requiring some external device (such as a grid-tie inverter) to control their output voltage.

The ability to have its input voltage adjusted, consequently adjusting the output voltage of the solar panels, is also necessary for the inverter's MPPT feature to work, which we will talk about next.

Functions and technical requirements of photovoltaic inverters
Figure 2 – Basic control blocks of a photovoltaic inverter

MPPT – Maximum Power Point Tracking

This is a very important feature, present in absolutely all photovoltaic grid-tie inverters. In order to extract the maximum amount of energy from a photovoltaic system, the panels must always operate at their maximum power point.

To achieve this, the inverters employ MPPT algorithms (Maximum power point tracking – tracking of maximum power point). The MPPT system works in conjunction with the inverter input voltage control system. The objective of the algorithm is to establish the ideal operating voltage value of the photovoltaic modules.

This information is sent to the voltage control system, which sets the solar panels to operate exactly (or as close as possible) to their maximum power point. The MPPT feature is useful (and necessary) so that the inverter can adapt to any type or quantity of photovoltaic modules (respecting the inverter's operational limits).

The MPPT and the voltage control system work together to make this adjustment possible. During an operating day, the maximum power point of photovoltaic modules varies according to irradiance (intensity of sunlight), temperature and the presence of shadows.

The inverter is then forced to adapt, constantly adjusting the operating voltage of the photovoltaic modules to seek their maximum power point.

Functions and technical requirements of photovoltaic inverters
Figure 3 – The MPPT system – maximum power point tracking – allows inverters to search for the optimal operating point of photovoltaic modules

Leakage current monitoring

In photovoltaic installations, as in any electrical installation, there may be undesirable leakage currents in equipment and components. Leakage currents are electrical currents that deviate from their original path and flow into the earth or pass through the body of a person or animal (when an electric shock occurs).

Leakage currents must be avoided as a protective measure, as their presence indicates the existence of faults or defects.

Functions and technical requirements of photovoltaic inverters
Figure 4 – The presence of leakage currents indicates the existence of faults or defects. The inverter must monitor leakage current and must automatically shut down when a leakage occurs

Desirable functions and characteristics in inverters

MPPT with global maximum power point search

The quality of an inverter's MPPT system says a lot about it. Normally in manufacturers' catalogs the efficiency of the equipment is specified, but the efficiency of the MPPT algorithm is never mentioned, that is, the inverter's ability to always seek the best operating point for the modules.

A bad MPPT system, even in a good quality inverter, can reduce the performance of the photovoltaic system, especially in non-ideal operating situations, with the presence of Shadows and dirt. The ability to search for global maximum power points (and not just local ones, as is the standard in most equipment) is very desirable in inverters.

Figure 5 – The presence of partial shadows makes it difficult to find the point of maximum global power in photovoltaic systems. A more sophisticated MPPT algorithm is needed to overcome this type of situation, preventing the inverter from being stuck at a local maximum. Photo: Fronius.

Multiple MPPT inputs

Inverters traditionally had only one MPPT input. This means that all strings of modules connected to the inverter, regardless of quantity, were treated as a single set.

The inverter with only one MPPT input tracks the maximum power point of the entire set of parallel strings, not being able to optimize the operation of the photovoltaic system when there are modules or strings operating in unequal situations (different inclinations and shadow conditions). , for example).

On the other hand, the MPPT multi-input inverter has the ability to look individually at strings or small groups of strings of PV modules, making the operation of the PV system more efficient.

The presence of some operational change in the strings of an input (such as a shadow) does not affect the strings that are linked to the other inputs. In equipment with multiple MPPT inputs, it is also possible to have strings with different characteristics (types and quantities of photovoltaic modules) connected to different inputs, as the inputs are absolutely independent.

Figure 6 – In the inverter with multiple MPPT inputs, the operation of each input is carried out independently, making it possible to have strings with different conditions and characteristics at each input

High conversion efficiency

This is a desired requirement in any type of equipment or machine and is not exclusive to photovoltaic inverters. Typically photovoltaic inverters have efficiencies of 96% to 98%. Efficiency measures how much energy is consumed within the equipment and is defined as the ratio between the output power and the input power of the inverter.

The efficiency of an inverter must always be as high as possible, as any small variation of just 1% can have a major impact on results over time. An energy loss of just 1% in a solar plant can represent a large amount of energy over the years. That is why the efficiency of the inverter is one of the first items that must be evaluated when choosing the equipment.

Figure 7 – Efficiency measures the amount of energy consumed in the inverter. It is defined as the ratio between the output power and the input power of the equipment

Low harmonic current content

A good current control system, combined with a good output filter, is necessary to enable the generation of currents with low distortion, without the presence of many harmonics. The NBR 16149 standard limits the harmonic content of the output current of grid-tie inverters in Brazil to 5%.

The lower the harmonic content, the lower the impact caused by the inverter to the electrical grid. The level of harmonic distortion of the inverter's output current must be low because large amounts of harmonic currents cause damage to the electrical network, mainly: increased losses, electromagnetic interference and resonances.

Figure 8 – The harmonic distortion rate of the electrical current produced by the inverter must be small. In this figure we see a typical waveform of the output current of a photovoltaic inverter. The current is sinusoidal and has a high frequency ripple content that must not exceed 5% of the total rms value of the current.

Wide input voltage range

Photovoltaic inverters have a minimum and maximum operating voltage limit. An inverter with wider limits, with a wider range of input voltage, allows greater flexibility in the composition of photovoltaic projects, allowing the same equipment to be used in projects with different types and quantities of modules in series.

Normally in inverters for microgeneration, with powers of up to a few kilowatts, the input voltages are more flexible, with a wider range. In inverters for power plants, this characteristic is already more restricted, with a narrow input voltage range and little choice in the number of string modules.

Figure 9 – A wider range of input voltage allows greater flexibility in using the inverter in different projects, with different types and quantities of photovoltaic modules
 

characteristics of inverters Globo Brasil grid-tie photovoltaic inverter
Marcelo Villalva
About the Author
Marcelo Villalva

Specialist in photovoltaic systems. Professor and researcher at the Faculty of Electrical and Computer Engineering (FEEC) at UNICAMP. Coordinator of LESF - Energy and Photovoltaic Systems Laboratory at UNICAMP. Author of the book "Photovoltaic Solar Energy - Concepts and Applications".

Comments (2)

Comments are moderated before publication.

Comments should be respectful and contribute to a healthy debate. Offensive comments may be removed. The opinions expressed here are those of the authors and do not necessarily reflect the views of the author. Canal Solar.

Leave your comment Cancel reply

  • Paulo Botelho Araruna 14/02/2022 · 12:20

    Congratulations Marcelo for the article, clear and objective explanation. Could you explain how the photovoltaic inverter can inject energy into the load, to the detriment of the energy from the grid, or better yet why the load is preferably powered by the photovoltaic system, instead of the energy from the grid, if they are in parallel, the two systems should act together.

    Reply
    • Deborah Garcez 15/02/2022 · 08:17

      Hello, Paulo, how are you? We appreciate the recognition! Contact our consultants and learn about the Fundamentals of Solar Energy course, which will help you with any questions: http://whts.co/CanalSolar-cursos. And read the article: https://canalsolar.com.br/funcoes-e-requisitos-tecnicos-dos-inversores-fotovoltaicos/

Posts

What could change with the White Tariff?
Technical Article

What could change with the White Tariff?

Lais Andrade · Oct 23
Photovoltaic O&M as a recurring revenue stream for integrators
Technical Article

Photovoltaic O&M as a recurring revenue stream for integrators

Raone Silva · Sep 18
Canal Solar Round-Trip Efficiency and its viability in battery storage projects.
Technical Article

Round-Trip Efficiency and its feasibility in battery storage projects

Thiago Farias · Aug 27
Technical Article

Certification of battery-based storage systems

Geraldo Silveira · Aug 27

Most Read

01

Check out the ranking of the 10 largest energy consumers in the world

Brazil ranks eighth on the list with 509 TWh, according to Worldometer

02

Solar energy certification: what is it, when and how to do it?

Find out why this process is essential and how to carry it out simply and efficiently

03

Battery for solar system: understand if it is worth installing

Learn about the different types of batteries, backup applications and benefits

04

The power went out during voting: will the electronic voting machine still work?

The devices have internal batteries with a runtime of approximately 12 hours; four models will be used this year.

05

Saving cables with leap-frog connection of photovoltaic modules

Understand the leap-frog strategy and learn how it allows you to reduce the cost of electrical cables in facilities

Categories

Market & InvestmentsInternational marketPolitics & RegulationProjects & ApplicationsSustainability & ESGTechnology & Innovation

Receive the news in your email.

Daily bulletin with the essentials of the solar sector.

✓ Registration confirmed!
Share
Canal Solar

This is a news and information channel about the photovoltaic solar energy sector. The content is protected by copyright law.

Categories
  • Market & Investments
  • International market
  • Politics & Regulation
  • Projects & Applications
  • Sustainability & ESG
  • Technology & Innovation
Institutional
  • About Us
  • Contact
  • Privacy
  • Quality policy
  • We’re hiring!
Place your ad

Your brand where energy sector decisions happen.

Download media kit
Group Canal Solar
Canal Solar EducationalCS ConsultingCanalVE
Associations and certifications
ABGDIEEECIGRÉCREA-SPABSOLAR Associate
Copyright © 2026 Canal Solar. All rights reserved. CNPJ: 29.768.006/0001-95 Developed by Softeo Technology
GDPR Cookie Banner

We use cookies to make your experience on this site better Find out more about the cookies we use or turn them off in your .

Canal Solar
Powered by  GDPR Cookie Compliance (opens in a new tab)
Privacy

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognizing you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.

Cookies strictly required

Strictly Necessary Cookie should be at all times so that we can save your preferences for cookie settings.

Cookies for third parties

This website uses Google Analytics to collect anonymous information such as the number of visitors to the site, and the most popular pages.

Keeping this cookie enabled helps us to improve our website.